Pick the our controller,
it will be best choice.
Sanup controllers are based on 56 years of accumulated technology.
The biggest characteristic of industrial electrical products is that it is easy and convenient for users to use it based on stable control and quality.


SDX Series
Perfect Timer Included
Call No.for Parameters Call
PWM Control Output

FEATURES
FEATURES
CALL Number
Default
Jump directly by entering the 'Call No.' of the parameter in the setting mode without going to a complicated path for parameter setting
FEATURES
Perfect Timer Included
Default
Timer function included for set to control start and stop time.
FEATURES
PWM Control Output
Default
SCR. SSR (Random Type). Triac direct driving output. Linear power control like to SCR power controller.
FEATURES
Case Structure for Internal Cooling
Default
Designed with comb-shaped vents to facilitate internal air circulation.
FEATURES
Parameter Setting Lock
Default
Parameter setting lock by user set password number for non-necessary parameter change
FEATURES
Heat or Cool Control Mode
Default
Settable control mode change to heat or cool control mode
FEATURES
Power
DC 24V Optional
Default 100~240Vac 50-60Hz. By order 24Vdc enable
SPECIFICATION
1. Power
Voltage: 100-240Vac or 24Vdc (Voltage F.Rate ±10% under)
Frenquency: 50-60Hz
Power Consuption: Max 10VA under
Isolation: between primary-secondary terminal: 500Vdc 20MΩ over
between primary-ground terminal: 500Vdc 20MΩ over
between ground-secondary terminal: 500Vdc 20MΩ over
Dielectric Strength: between primary-secondary terminal: 2300Vac 50/60Hz 1min.
between primary-ground terminal: 2300Vac 50/60Hz 1min.
between ground-secondary terminal: 1500Vac 50/60Hz 1min.
2. Input
Input: Thermocouples K J E R T
RTD DIN Pt100℃
Vdc/mAdc 1-5Vdc 4-20mAdc
Scan Time: 250ms
Impedance: T.C 1MΩ over
Accuracy: T.C ±0.3% + 1 digit 또는 ±3℃ of big
RTD ±0.2% + 1 digit
3. Output
Relay: 250Vac. 2A (R load)
SSR: 17Vdc Pulse. 20mA max.
Current: 4-20mAdc Max 600Ω less
Alarm: 250Vac. 1A (R load)
4. Control
PID control by Auto-Tuning. PI. PD Control. (PID Control, ARW is auto set)
M.R. included Proportional (P) Control
ON-OFF Control with Hysteresis
Reverse or Direct Control Mode
Output Limit: Settable Output High and Low Limit
Control Period: 1-60sec. (not for 4-20mA)
5. Operating Condition
Temperature : 0-50℃
Humidity: 35-85%RH (No condensation)
Magnetic: 400AT/m less
Warm-Up Time: Min. 30min more
6. Storage
-25~70℃ / 5~95%RH (No condensation)
PARAMETER CALL BY CALL No.

PWM CONTROL OUTPUT

OUTPUT FORM

SSR OUTPUT

PWM OUTPUT

PANEL CUT SIZE

WIRING

HOW TO ORDER